ports | threads G 1 1/2 - G 2 flanges PN 16/40/100 |
function | NC |
pressure range | 0-16 / 0-40 / 0-64 bar |
KV value | 18,4 m³/h |
media | gaseous liquid highly viscous gelatinous contaminated |
flow direction | A B as marked |
switching cycles | 90 1/min |
switching time | opening 520 ms closing 150 ms |
media temperature | DC -20 °C — +100 °C AC -20 °C — +100 °C |
ambient temperature | DC -20 °C — +80 °C AC -20 °C — +80 °C |
weight | MK 14,0 kg FK 18,0 kg |
nominal voltage | Un 24 V DC Un 230 V 40-60 Hz AC |
actuation | DC direct-current magnet AC direct-current magnet with integrated rectifier |
insulation rating | H 180 °C |
protection | IP65 |
energized duty rating | ED 100% |
connection | plug acc. DIN EN 175301-803, form A, 4 positions x 90°, wire diameter 6-8 mm |