- Durag D-R 290 Opacity & Dust Monitor
Durag D-R 290 Opacity & Dust Monitor
Update Terakhir
:
07 / 02 / 2025
PT. Surrama Tridaya Mandiri adalah perusahaan yang bergerak dalam bidang usaha importir , distributor alat-alat instrument : flowmeter, gas detector, control valve, safety valve, pressure reducing valve, dll
Detail Durag D-R 290 Opacity & Dust Monitor
D-R 290 Opacity & Dust Monitor
Overview
- Continuous and contactless measurement
- Automatic zero and span check
- Automatic measurement and correction of contamination of optical surfaces
- Extremely powerful and stable super-wide band diode (SWBD) light source
- Extremely low-maintenance
- Fail-safe shutters with purge air monitoring as option
- Certified according to EN 15267-3
- Compliant with US-EPA 40 CFR 60 PS1, PS11, and ASTM D6216 - 12
Benefits
- Certified for official emission monitoring
Type approved according to EN 15267-3, compliant with the requirements of US-EPA 40 CFR 60 PS1, PS11, and ASTM D6216 - 12 - Easy set-up for opacity monitoring
No gravimetric calibration needed when using transmission principle for reliable opacity monitoring - Broad functional range due to dual-path transmission principle
The sensitivity scales up with growing duct diameter. This allows for measuring very low dust concentrations in very big stack diameters and vice versa very high dust concentrations in small stack diameters - Suitable for harsh flue gas conditions
Non-contact measurement with purge air cushion technology allows for very high flue gas temperatures and aggressive flue gases - Durable through options purge air monitoring and fail safe shutter
Protection of the device through continuously monitored purge air supply and automatic closure of fail safe shutter in case of purge air failure - Rugged design for harsh environmental conditions
Suitable for a wide range of application due to heavy duty metal housing, a broad ambient temperature range and optional versions for EX environments - Reliable emission monitoring
Automatic control functions ensure reliable measuring values
Technical Data
Measuring principle | Measuring the optical transmission of visible light which passed a measuring path twice. |
Conformities | IED 2010/75/EU / 17. BImschV 2001/80/EG LCPD / 13. BImschV 27. BImschV EN 13284-2, EN 14181 EN 15267-3 40 CFR 60 US EPA PS1 40 CFR 60 US EPA PS11 ASTM D6216 - 12 |
Certificates | CE, QAL1 DIN EN 14181 / DIN EN ISO 14956 / EN 15267-3, MCERTS, Pattern Approval GOST R, Pattern Approval certificate Rep.of Belarus, Pattern Approval Certificate PRC, MCOC 40CFR 60 EPA PS1 |
Measuring location | In-situ, non-contact |
Self-check, protective functions | Automatic zero- and span check Automatic soiling correction LED light source: no readjustment needed Automatic fail safe shutter in case of purge air failure (option) |
System components | D-R 290 M xx2 measuring device D-R 290 R xx2 reflector D-ISC 100 Universal operating and display unit D-BL purge air unit D-R 290 E mounting flange with tube D-SK fail safe shutter (option) Accessories |
Tampilkan Lebih Banyak