Operation mode |
MAN (Manual) |
Use the UP and DOWN keys to set a flow rate. |
EXT |
Analog fixed operation |
4 – 20, 0 – 20, 20 – 4, 20 – 0 mA (Proportional to the discharge rate) |
Analog variable operation |
Programmable 2-point setting (Input signal DC 0 – 20 mA, proportional to the discharge rate) |
Pulse control Note 1 |
D150: 0.01560 mL/PLS – 300 mL/PLS D300: 0.03120 mL/PLS – 600 mL/PLS |
Batch control Note 1 |
D150: 15.6 mL/PLS – 300 L/PLS D300: 31.2 mL/PLS – 600 L/PLS |
Interval batchcontrol Note 1 |
Day: 0 – 9, Hour: 0 – 23, Minute: 1 – 59 |
Capacity D150: 15.6 mL/PLS – 300 L/PLS D300: 31.2 mL/PLS – 600 L/PLS |
Profibus control |
Communication protocol: Profibus-DP-compliant international standard: EN50170 (IEC61158) |
Input |
STOP / Pre-STOP / AUX / Interlock |
No-voltage contact or open collectorNote 2 |
Analogue |
0 – 20 mADC (Internal resistance is 200Ω.) |
Pulse |
No-voltage contact or open collector Max pulse frequency is 100Hz. |
Output |
Alarm 1 (OUT1) |
Non-voltage contact (mechanical relay): AC 250 V, 3 A (resistive load)Each output item is selected by Enable/Disable. Batch completeNote 3/STOP/Pre-Stop/Interlock/Leak Detection/Motor Overload/Drive Error |
Alarm 2 (OUT2) |
Non-voltage contact (photo relay): AC/DC 24 V, 0.1 A (resistive load)Each output item is selected by Enable/Disable. Volume Prop. PLSNote 4/Batch completeNote 3/STOP/Pre-Stop/Interlock/Leak Detection/Motor Overload/Drive Error |
External power supply |
DC 12 V, 30 mA or less |
Current |
DC 0 to 20 mA, Two-point setting (allowable load resistance: 300 Ω) |